199.68 kWh rated energy
Eight 24.96 kWh liquid-cooled packs use NFPP 160 Ah sodium-ion cells, arranged across two separate battery channels.

One integrated platform for commercial energy management. Nexus TerraShield 200 brings together 199.68 kWh of NFPP sodium-ion battery energy, 200 kW of installed bidirectional conversion capacity, liquid cooling and coordinated EMS/BMS control in an IP54 outdoor cabinet.

Eight 24.96 kWh liquid-cooled packs use NFPP 160 Ah sodium-ion cells, arranged across two separate battery channels.
Two 100 kW PCS modules and two DC/DC converters manage bidirectional energy flow. The separate 0.8P battery rating, state of charge and temperature determine the project operating power.
A service-accessible cabinet brings together battery packs, power electronics, intelligent controls and layered protection.
Our factory photographs show the AuroraCell cabinet, its integrated battery and power electronics, and the local monitoring interface.



Photographs show a factory configuration. Equipment and screen settings are confirmed for each project. Select any image to view it in full size.
Dispatch stored energy against site demand peaks to support commercial load management.
Store surplus solar energy through a compatible AC-coupled PV installation. Direct DC solar connection requires a separately engineered MPPT solution.
Coordinate charging and discharging around time-of-use prices through the EMS.
Compatible with backup and off-grid applications when the standard version is upgraded. We define the required switching equipment, auxiliary power and controls around your site.
Integrate storage with PV, site loads and, where required, a generator through a project-specific control and protection design.
The PCS supports active and reactive power control. Site requirements, available power and the external control interface are agreed during project engineering.
A 6 kW liquid-cooling system supports temperature control across the battery packs. The specified cabinet ambient range is −25°C to +55°C, with derating above +45°C.
Pack-level aerosol suppression works alongside cluster-level smoke and temperature detection, high-voltage protection and emergency-stop functions.
The cabinet EMS and BMS provide coordinated operation and monitoring. Ethernet and RS485 support integration; external dispatch functions and register access are confirmed for your control system.
| Installed conversion capacity | 200 kW (2 × 100 kW PCS) |
|---|---|
| Rated battery energy | 199.68 kWh |
| Cell technology | NFPP sodium-ion, 3 V / 160 Ah |
| Battery architecture | 8 × 24.96 kWh packs; 2 separate channels of 4 packs |
| Power path | Battery → DC/DC → PCS; channels combined on the AC side |
| Battery operating rating | 0.8P; project power depends on SOC, temperature and system limits |
| Backup & off-grid | Compatible with an upgrade to the standard version |
| PV integration | AC-coupled; no direct-PV MPPT hardware in the standard cabinet |
| AC output / grid range | 400 V, three-phase four-wire / 340–460 V |
| Standard operating mode | Grid-connected energy management |
| Outdoor enclosure | IP54 |
|---|---|
| Cooling | Liquid cooling, 6 kW capacity |
| Cabinet ambient temperature | −25°C to +55°C; derating above +45°C |
| Cell charge temperature | 0°C to +55°C |
| Cell discharge temperature | −40°C to +55°C |
| Humidity / altitude | 0–95% RH, non-condensing; derating above 2000 m |
| Communication / protocols | Ethernet, RS485 / Modbus TCP, Modbus RTU |
| Cabinet body (W × D × H) | Approx. 1650 × 1380 × 2435 mm; excludes pallet and projections |
| Approximate weight | 3200 kg |
| Noise | ≤75 dB(A) |
We size each project using the battery operating limits, usable energy, conversion losses and auxiliary loads. Installed converter capacity is separate from continuous AC output. We confirm the operating envelope, performance criteria, grid requirements and warranty scope in your project offer.
It is our integrated outdoor sodium-ion energy-storage cabinet for commercial and industrial applications, with 199.68 kWh rated battery energy and 200 kW of installed power-conversion hardware. The continuous operating power and usable energy are defined for your project.
Yes, with an upgrade to the standard grid-connected version. The required transfer equipment, auxiliary power supply, protection and controls are specified for the site. Backup loads, transfer behaviour and islanded operation are agreed and tested as part of the project.
The standard cabinet has no direct-PV MPPT hardware. Solar storage can be integrated through a compatible AC-coupled PV system. Direct DC coupling needs a separately engineered MPPT configuration, with controls and protection matched to the project.
Yes. Nexus TerraShield uses 6 kW liquid cooling as part of its integrated thermal-management system. Its NFPP battery architecture and cabinet design are distinct from other sodium-ion products in the AuroraCell portfolio.
The cabinet supports energy-management strategies such as peak shaving, AC-coupled PV shifting and tariff optimisation. We align the cabinet EMS, external dispatch interface, metering and site protection with your requirements.
Share your load profile, PV generation, grid connection and project location. Tell us whether you need grid-connected operation, backup or a fully off-grid solution, and we will help define the suitable configuration and upgrade scope.
Request a Nexus TerraShield discussion ↗Related