SEO CONTENT PREVIEW · FOR REVIEW · All cell previews

Sodium-Ion Battery Cells / 10 Ah

10 Ah / Cylindrical / Layered oxide

32140 High-Power Sodium-Ion Cell

High current. Cold-weather readiness. The AuroraCell 32140 sodium-ion cell combines 10Ah capacity with up to 180A continuous discharge, 300A pulse discharge for 3 seconds and controlled charging below zero.

AuroraCell 32140 High-Power Sodium-Ion Cell
Cell-specific advantages

Built for demanding power applications.

300A pulse capability

Deliver up to 300A for 3 seconds and up to 180A continuously at 10°C to 45°C. A strong fit for starting, motors, actuators and industrial peak-power demands.

Charge down to −20°C

Controlled sub-zero charging can reduce preheating demand and help outdoor systems stay ready. The BMS applies the datasheet’s temperature-dependent charging limits.

A flexible 10Ah building block

The cylindrical format, 30Wh energy and 3.0V nominal voltage support modular pack configurations for robotics, industrial mobility, backup and starter applications.

Technical overview

Key specifications.

Starter and SLI packs, AGVs and AMRs, outdoor industrial equipment and high-power backup.

AuroraCell combines cell supply with selection support, R&D, battery design and technical integration for European projects.

Explore sodium-ion technology and test results ↗

Nominal capacity / energy 10 Ah / 30 Wh
Nominal voltage 3.0 V
Continuous discharge Up to 18C / 180A at 10°C to 45°C
Pulse discharge Up to 30C / 300A for 3 seconds at 10°C to 45°C
Charge temperature −20°C to +55°C, with temperature-dependent limits
Discharge temperature −40°C to +60°C
Fast charging Up to 5C / 50A under defined conditions
Dimensions (diameter × height) 33.2 × 140.0 mm

Ratings apply within the cell’s specified operating conditions. The full technical datasheet defines pulse duration and temperature-dependent limits.

Product questions

From specification to application.

Can this sodium-ion cell charge below freezing?

Yes. The 32140 supports controlled charging down to −20°C within the datasheet’s current, voltage and state-of-charge limits. This is a cell-specific capability.

What is the difference between its continuous and pulse ratings?

At 10°C to 45°C, the specified maximum is 180A continuously or 300A for a 3-second pulse. Temperature-specific limits are provided in the technical datasheet.

Build your next battery with AuroraCell.

Share your system voltage, energy, peak current, operating temperature and project volume. We’ll help you select the cell and define the next engineering step.